Energy Efficiency Compliance Checklist Part 9 Non Residential Buildings

Published by Ministry of Municipal Affairs and Housing under Toronto Building Forms Index

Agencies
Ministry of Municipal Affairs and Housing
Applies to
designer
Work types
new construction
Signatories
designer

The energy efficiency compliance checklist for Part 9 non-residential buildings, based on Ontario Building Code Supplementary Standard SB-10 Division 4, filed in Toronto Building's forms index for applications prior to December 31, 2017. It opens with a scope test — Part 9, non-residential occupancy only, heating other than electric space heating, winter occupancy, fenestration to wall ratio no more than 40% — then works through envelope thermal performance by degree-day zone, air infiltration, HVAC, ducts and piping, service water heating, lighting and its controls, and electric motors.

What it covers

  • Designer Information
  • Energy Efficiency Design
  • Thermal Performance of the Building Envelope
  • Table 1.1.1.2 Building Envelope Requirements Based on Degree Day Zones (SI)
  • Air Infiltration, Article 1.1.1.3
  • Heating, Ventilating and Air Conditioning, Article 1.1.1.4
  • Ducts, Plenums and Piping, Article 1.1.1.5
  • Table 1.1.1.5. Minimum Thickness of Pipe Insulation
  • Service Water Heating, Article 1.1.1.6
  • Lighting, Article 1.1.1.7
  • Interior Lighting, Article 1.1.1.8
  • Interior Lighting Controls, Article 1.1.1.9
  • Exterior Lighting, Article 1.1.1.10
  • Exterior Lighting Controls, Article 1.1.1.11
  • Electric Motors, Article 1.1.1.12
Check this against the municipality before you rely on it. DocHub collects what a municipality published; it cannot tell you what is in force today. A newer version may exist, may be titled differently, or may not be posted publicly at all.
Publisher
Ministry of Municipal Affairs and Housing
Category
Energy compliance
Published under
Toronto Building Forms Index — the municipality's own heading
Form ref
Ontario Building Code Supplementary Standard SB-10 Division 4
Instruments
Ontario Building Code Supplementary Standard SB-10 · O.Reg. 332/12
Document date
December 23, 2013
Building types
non-residential
Publisher note
The checklist states it is made available for code users by the Ministry of Municipal Affairs and Housing; the City of Toronto distributes it through the Toronto Building forms index, under applications prior to December 31, 2017.
Tags
checklistenergy-efficiencysb-10non-residentialpart-9
Energy Efficiency Compliance Checklist Part 9 Non Residential BuildingsOpen at toronto.ca