Toronto · Checklistswritten

Laneway Suites: Fire Access Requirements

Published by City of Toronto — Toronto Building under Providing Fire Department Access To A New Laneway Suite

Applies to
any
Work types
laneway suite
Document date
September 8, 2020
Building types
residential

The report to the Planning and Housing Committee from the Chief Building Official and Executive Director, Toronto Building, published with the City's guidance on fire department access to a new laneway suite. It traces the access options developed since laneway suites were permitted city-wide — a side yard path, a path shared under a limiting distance agreement, the public lane — then a 2019 Building Code Commission decision on a 73-metre travel distance, two mitigating options taking that distance to 90 metres, and a path width moving to 0.9 metres.

What it covers

  • Summary
  • Recommendations
  • Financial Impact
  • Decision History
  • Comments
  • Laneway Suite Design: Meeting Fire Access Requirements
  • Toronto Fire Services Requirements: Clear Path of Travel
  • Meeting Emergency Access Requirements
  • Sharing the Path of Travel for Fire Access
  • Alternative Solutions
  • Building Code Commission Decision
  • Recommended Compliance Alternatives
  • Amending Requirement for an Unobstructed 1.0 metre Path of Travel
  • Amendments to the Ontario Building Code
  • Impact of the Generic Alternative Solution on Laneway Suites Construction
  • Conclusion and Next Steps
  • Contact
Check this against the municipality before you rely on it. DocHub collects what a municipality published; it cannot tell you what is in force today. A newer version may exist, may be titled differently, or may not be posted publicly at all.
Publisher
City of Toronto — Toronto Building
Category
Checklists
Published under
Providing Fire Department Access To A New Laneway Suite — the municipality's own heading
Alias
PH16.10 'Laneway Suites: Fire Access Requirements'
Agencies
Toronto Building · Toronto Fire Services · City Planning · Planning and Housing Committee
Instruments
Ontario Building Code · Ontario Building Code Act
Signatories
Chief Building Official & Executive Director, Toronto Building
Tags
staff-reportlaneway-suitefire-accessalternative-solutiontoronto-fire-services