Design Criteria for Sanitary Sewers, Storm Sewers and Forcemains for Alterations Authorized under an Environmental Compliance Approval

Published by City of Hamilton

This is the City of Hamilton’s document, as published on its website on 19 October 2026. The municipality may have changed it since: check the current version at the source. Legal notice

Type
Form
Published by
City of Hamilton
Date
May 5, 2023
Also called
Design Criteria for Sanitary Sewers, Storm Sewers and Forcemains for Alterations Authorized under an ECA
For
designer
Building types
All building types
Pages
61
Agencies
Ministry of Environment, Conservation and Parks
Instruments
Ontario Water Resources Act, R.S.O. 1990, c. O.40 · Environmental Protection Act, R.S.O. 1990, c. E.19

Overview

The Ministry of Environment, Conservation and Parks' design criteria, version 2.0 of May 5, 2023, for alterations to municipal sewage collection and stormwater systems authorized under an Environmental Compliance Approval (ECA), linked from Hamilton's Municipal Systems Alterations page. It sets minimum design criteria for sanitary sewers, forcemains, combined sewers, storm sewers and third pipe collection systems, from design flows, pipe diameters and velocities to maintenance holes and catch basins, then documentation and inspection, leakage, deflection and hydrostatic testing, with appendices on source water protection.

What it covers

  • Preface
  • Definitions
  • Introduction
  • Design of Sanitary Sewers
  • Design of Forcemains
  • Combined Sewers
  • Storm Sewers
  • Third Pipe Collection System
  • Documentation
  • Inspection and Testing for Sanitary Sewers, Storm Sewers and Forcemains
  • Appendix I: Identification of Risks to Sources of Drinking Water
  • Appendix II: Source Protection Standard Operating Policies