Fire Protection for Gas and Electric Ranges

Published by City of Markham

This is the City of Markham’s document, as published on its website on 18 October 2026. The municipality may have changed it since: check the current version at the source. Legal notice

Type
Guide
Published by
City of Markham
Date
January 1, 2025
For
builder
Building types
All building types
Pages
2

Overview

Markham's Builder Tip Issue No. 14, dated January 1, 2025 and updated to the 2024 Ontario Building Code, on clearances around kitchen cooktops, filed with the City's housing tips. It quotes Article 9.10.22.2. on the 750 mm vertical clearance to framing, finishes and cabinets, reducible to 600 mm with noncombustible materials or a metal hood, and Article 9.10.22.3. on protecting combustible surfaces within 450 mm. The Objective explains the risk of a custom combustible hood matching the cabinets and shows a typical kitchen elevation.

What it covers

  • 9.10.22.2. Vertical Clearances above Cooktops
  • 9.10.22.3. Protection Around Cooktops
  • Objective