This is the City of Markham’s document, as published on its website on 18 October 2026. The municipality may have changed it since: check the current version at the source. Legal notice
Markham's Builder Tip Issue No. 10, dated January 1, 2025 and updated to the 2024 Ontario Building Code, on concrete and masonry work below 5 °C, filed with the City's housing tips. It quotes Article 9.3.1.9. on concrete temperatures for 72 hours after placing, and Articles 9.20.14.1. and 9.20.14.2. on mortar and masonry temperatures and covering unfinished work. The Objective notes early freezing can cut concrete strength by 30%, and the second page gives practices for concrete work, mortar mixing and masonry laying, including heater ventilation.