Overview

Markham's Builder Tip Issue No. 10, dated January 1, 2025 and updated to the 2024 Ontario Building Code, on concrete and masonry work below 5 °C, filed with the City's housing tips. It quotes Article 9.3.1.9. on concrete temperatures for 72 hours after placing, and Articles 9.20.14.1. and 9.20.14.2. on mortar and masonry temperatures and covering unfinished work. The Objective notes early freezing can cut concrete strength by 30%, and the second page gives practices for concrete work, mortar mixing and masonry laying, including heater ventilation.

What it covers

  • 9.3.1.9. Cold Weather Requirements
  • 9.20.14.1. Laying Temperature of Mortar and Masonry
  • 9.20.14.2. Protection from Weather
  • Objective
  • Concrete Work
  • Mortar Mixing
  • Masonry Laying