Builder Tip No. 26 from Markham's Building Standards Department, dated January 1, 2025, listed with the City's non-housing tips under the 2024 Ontario Building Code. It quotes Article 3.8.2.1. on the areas a barrier-free path of travel reaches and its exceptions, and Sentence 3.8.3.3.(15) on glass doors in that path, marked with a continuous opaque strip at least 50 mm wide, colour and brightness contrasted, between 1350 mm and 1500 mm above the floor, with logos allowed within limits. A drawing shows the strip's width and height.

What it covers

  • 3.8.2.1. Areas requiring Barrier-Free Path of Travel
  • 3.8.3.3. Doorways and Doors
  • Objective
Check this against the municipality before you rely on it.