MarkhamBuilding InspectionsInspections
Published by City of Markham
This is the City of Markham’s document, as published on its website on 18 October 2026. The municipality may have changed it since: check the current version at the source. Legal notice
For staggered townhouses, Markham's Builder Tip Issue No. 42, dated January 1, 2025 and listed as Staggered Town Housings 45 Minute Fire-Resistance Rated Wall among the City's 2024 Ontario Building Code housing tips. It quotes Article 9.10.3.1. on Part 3, SB-2 and SB-3 ratings and Sentences 9.10.15.5.(1), (1.1) and (2) on exposing building faces and cladding at limiting distances under 0.6 m. The Objective cites SB-2 for the 45 minute and header ratings, names labelled vinyl siding over 12.7 mm exterior gypsum sheathing, and refers to Builder Tip No. 40.
DocHub collects what a municipality published; it cannot tell you what is in force today. A newer version may exist, may be titled differently, or may not be posted publicly at all.