Builder Tip Issue No. 40 from the City of Markham Building Standards Department, dated January 1, 2025 and filed with its 2024 Ontario Building Code housing tips, on vinyl siding within 2 feet of the property line. It quotes Article 9.10.3.1. and Sentences 9.10.15.5.(1), (1.1) and (2) on cladding under 0.6 m, including the CAN/ULC-S134 test. The Objective explains how SB-2 sets the 45 minute and header ratings and names vinyl with a flame-spread rating of 25 or less, at most 2 mm thick, over 12.7 mm exterior gypsum sheathing.