Overview

Builder Tip Issue No. 27 from the City of Markham Building Standards Department, dated January 1, 2025, updated to the 2024 Ontario Building Code and listed among its housing tips, on the gas fireplace vent where it passes through the air and vapour barrier. It quotes Sentences (6) and (8) of Article 9.25.3.3. on sealing penetrations and the clearances around chimneys and gas vents with noncombustible material and high-temperature caulking. The Objective describes the projecting fireplace enclosure, gypsum board lining it, and insulating and sealing before the fireplace is set.

What it covers

  • 9.25.3.3 Continuity of the Air Barrier System
  • Objective
Check this against the municipality before you rely on it.