Issue No. 11 of the City of Markham Building Standards Department's Builder Tips, dated January 1, 2025, updated to the 2024 Ontario Building Code and listed with the City's housing tips. It quotes Articles 9.23.5.1. to 9.23.5.4. on holes drilled in roof, floor and ceiling members, notching of joists near bearing, and the undamaged portion left in wall studs and top plates. The Objective concerns drilling and notching for pipes, cables and other services, with illustrations and a table of the hole and notch sizes and locations.