This is the City of Markham’s document, as published on its website on 18 October 2026. The municipality may have changed it since: check the current version at the source. Legal notice
The City of Markham's four-page Builder Tip No. 25, dated January 1, 2025 and updated to the 2024 OBC, on accessible washrooms in non-housing buildings, filed with the City's non-housing tips under the 2024 Ontario Building Code. It quotes Sentences 3.8.3.8.(3) to (9) on grab bars in water closet stalls: the 750 mm L-shaped bar, the bar behind the toilet at 840 mm to 920 mm, fold down grab bars, 1.3 kN loads, diameters and wall clearances, and Sentence 3.8.3.12.(1) on universal washrooms. A diagram shows mounting heights and clearances.