Issue No. 7 of the City of Markham's Builder Tips, dated January 1, 2025 and listed with its 2024 Ontario Building Code housing tips, on keeping stair risers uniform where a flight lands on ceramic, porcelain or marble flooring. It quotes Article 9.8.4.4., Uniformity and Tolerances for Risers, Runs and Treads, with its 5 mm and 10 mm tolerances, and Article 9.8.4.1., Dimensions for Risers. The Objective explains why the first riser is critical, suggests oversizing it or shimming, and points to Builder Tip No. 54.